Skip to main content
. 2023 Jan 25;11:1104569. doi: 10.3389/fchem.2023.1104569

TABLE 2.

Experimental data obtained on the sample, using different setups. The confidence limits (LFL-UFL and ΔC) were calculated only for the respirable fibres count, following the methodologies reported in the text.

Lab 1_Au layer Lab 2_C layer Lab 2_Au layer
Respirable WHO fibres Number of fibres evaluated (L > 5 µm) 228 126 142
Concentration [f/L] 4.44·107 2.85·107 3.21·107
LFL 4.13·107 2.49·107 2.66·107
UFL 4.76·107 3.54·107 3.74·107
Concentration [µg/L] 39.49 103.43 66.60
ΔC [µg/L] 18.48 25.93 15.62
Average mass of a fibre [µg] 8.91 10−7 3.63 10−6 2.08 10−6
All fibres Total number of fibres (all lengths) 241 184 183
Concentration [f/L] 4.97·107 4.16·107 4.14·107
Concentration [µg/L] 39.63 107.22 77.60
Average mass of a fibre [µg] 8.45 10−7 2.58 10−6 1.87 10−6
% respirable fibres 94.6% 68.5% 77.6%
% fibres W < 0.2 µm 95% 59% 50%
Number of bundles (W > 0.5 µm) 3 4 4
Mean fibre aspect ratio 168.4 70.2 74.5