Skip to main content
. 2023 Feb 7;13:2172. doi: 10.1038/s41598-023-29228-1

Table 2.

Experimental data of palbociclib solubility in ScCO2.

T (K) P (MPa) ρCO2a (kg∙m−3) y × 105 (mole fraction) Std (y) × 105 (mole fraction)b U(y¯) × 105 (mole fraction)c Solubility (g∙L−1)
308 12.0 769 0.391 0.012 0.027 0.0305
15.0 817 0.501 0.024 0.053 0.0415
18.0 849 0.552 0.021 0.047 0.0475
21.0 875 0.627 0.011 0.034 0.0557
24.0 896 0.697 0.012 0.036 0.0635
27.0 914 0.914 0.021 0.056 0.0849
318 12.0 661 0.221 0.010 0.022 0.148
15.0 744 0.349 0.015 0.033 0.264
18.0 791 0.419 0.012 0.030 0.337
21.0 824 0.738 0.011 0.038 0.618
24.0 851 0.860 0.013 0.043 0.743
27.0 872 1.242 0.041 0.096 0.1101
328 12.0 509 0.110 0.004 0.009 0.0057
15.0 656 0.210 0.004 0.012 0.0140
18.0 725 0.281 0.013 0.030 0.0206
21.0 769 0.840 0.019 0.053 0.0656
24.0 802 0.972 0.021 0.059 0.0792
27.0 829 1.468 0.032 0.091 0.1235
338 12.0 388 0.081 0.003 0.007 0.0031
15.0 557 0.137 0.002 0.007 0.0078
18.0 652 0.211 0.003 0.011 0.0139
21.0 710 0.981 0.041 0.093 0.0708
24.0 751 1.197 0.011 0.057 0.0914
27.0 783 2.027 0.091 0.202 0.1613

*Standard uncertainty values (u) for temperature and pressure are u(T) = 0.1 K and u(P) = 0.1 MPa.

aCO2 density was obtained from national institute of science and technology (NIST) chemistry webbook (http://webbook.nist.gov/chemistry/).

bExperimental standard deviation was obtained by Stdyi=j(yj-y¯)/n-1.

cExpanded uncertainty was determined from U(y¯)=k·ucomb with the coverage factor k = 2 (the level of confidence of approximately 95%) and the relative combined standard uncertainty ucomb/y¯=iPi·uixi/xi2.