Skip to main content
. 2018 Oct 22;136(5):390–397. doi: 10.1590/1516-3180.2018.0022170418

Table 3. Accuracy of different tests for diagnosing Alzheimer’s disease.

Instruments AUC P 95% CI Sensitivity (%) Specificity (%) Cutoff point
CAMCOG 0.975 < 0.0001 94-99 95 93 75 points
MMSE 0.972 < 0.0001 93-99 93 93 23 points
Constructive praxis 0.905 < 0.0001 85-95 69 98 4 points
Total praxis 0.858 < 0.0001 79-90 73 84 9 points
Ideomotor praxis 0.568 0.111 49-65 66 44 4 points

AUC = area under the curve; CI = confidence interval; CAMCOG = Cambridge Cognitive Examination; MMSE = Mini-Mental State Examination. P from chi-square test.