Effects of image preprocessing on accuracy for both datasets.

Dataset Classification Image Preprocessing SVM LR RF
First Dataset Abnormal vs. Normal Yes 0.967 0.969 0.923
No 0.956 0.95 0.77
AMD vs. DME Yes 0.909 0.926 0.851
No 0.923 0.931 0.762
CNV vs. DRUSEN Yes 0.964 0.977 0.933
No 0.954 0.963 0.874
Second Dataset Abnormal vs. Normal Yes 0.97 0.976 0.94
No 0.986 0.983 0.896
AMD vs. DME Yes 0.936 0.933 0.91
No 0.88 0.863 0.72