Residual antibacterial activity of Ag/Cu-CTS composite after long-term laundering.

Runs of Laundering Diameter of Inhibition Zone against E. coli (mm)
0 12.7
20 12.2
40 10.5
60 10.1
80 8.7
100 8.1
120 8.0
140 8.0
160 7.3