Table 1.

Overview of the water contact angles of the clean, pre-treated, unfouled surface (θclean), the oleic-acid-fouled surface before UV irradiation (θ0), the final contact angle after UV irradiation (θf) and irradiation time needed. A dash (-) is used for values that could not be measured.

Sample θclean (°) θ0 (°) θf (°) tf (min)
DuEL TiO2 20 ± 7 71 ± 20 16 ± 4 20
DuEL Architectural panel A 5 ± 4 52 ± 2 20 ± 4 360
DuEL Architectural panel B 3 ± 2 52 ± 2 23 ± 1 3000
SaniCoat 88 ± 5 46 ± 4 49 ± 1 360
CleanRock 71 ± 17 64 ± 16 50 ± 1 420
Architectural panel B 43 ± 6 53 ± 1 51 ± 1 2520
LVT treated 70 ± 13 78 ± 5 61 ± 8 1680
Roofing material 57 ± 3 61 ± 6 67.7 ± 0.5 120
Surface material B 78 ± 8 87 ± 8 81.0 ± 0.4 360
Surface material A 77 ± 7 79 ± 8 82 ± 2 360
LVT ref 93 ± 7 87 ± 5 87 ± 1 1710
Carpet tile treated - ± - - ± - - ± - -
Carpet tile ref - ± - - ± - - ± - -