Table 3.
Criteria values used for the decision matrix.
Criteria | Measurement Units | Values | ||||
---|---|---|---|---|---|---|
Low | Not Low | Medium | Not High | High | ||
LiFi capacity | Mbps | 0–427 | 427–432 | 432–437 | 437–442 | 442–447 |
WiFi capacity | Mbps | 0–10 | 10–30 | 30–60 | 60–90 | 90–120 |
LiFi CDT | Time (s) | 0– 0.5 | 0.6–1.625 | 1.626–2.75 | 2.76–3.875 | 3.876–5 |
Occurrence rate | n/min | 0–0.1 | 0.1–5 | 5–10 | 10–15 | 15–20 |
Occupation rate | n | 0–0.1 | 0.1–0.25 | 0.25–0.5 | 0.5–0.75 | 0.75–1 |