Peak to peak value and attenuation of experimental data.

Wavelength Surface Wave Air Underwater Attenuation Percentage Difference
2 mm Rayleigh 1.9 V 0.17 V 21 (dB) 4%
3 mm Rayleigh 0.6 V 0.171 V 10.9 (dB) 7.63%
4 mm Rayleigh 0.422 V 0.161 V 8.4 (dB) 5.2%
5 mm Rayleigh 0.551 V 0.167 V 10.4 (dB) 0.96%
5 mm Lamb 0.496 V 0.113 V 12.8 (dB) 2.34%