Laser beam source and optical setup used for the investigation.

Dimension Unit Trumpf TruDisk 3022
Wavelength (λ) [nm] 515
Laser power (Pmax) [W] 3000
Fiber diameter (dLLK) [µm] 200
Focal length collimator (fC) [mm] 150
Focal length optics (fF) [mm] 255
Focal diameter (dF, measured) [µm] 342.5
Diffraction factor (M2) [-] 46.1
Divergence angle (θ) [mrad] 88.2
Beam parameter product (BPP) [mm∙mrad] 7.55