Summary of values for the thermal diffusivity coefficient calculated using the back-calculation procedure.

Sample No. Bulk Density RMSE a
[kgm3] [%] [m2s]
1.1 2318 2.98 1.273 ×106
1.2 2322 3.80 1.236×106
1.3 2317 4.44 1.218×106
1.4 2321 1.84 1.233×106
mean value/uncertainty 2319 ± 3 (1.240 ± 0.053)×106
2.1 1175 1.47 0.477×106
2.2 1172 1.09 0.524×106
2.3 1174 1.30 0.506×106
2.4 1172 1.16 0.578×106
mean value/uncertainty 1173 ± 2 (0.520 ± 0.096)×106
3.1 772 2.00 0.448×106
3.2 776 1.22 0.410×106
3.3 777 1.88 0.370×106
3.4 767 2.61 0.381×106
mean value/uncertainty 773 ± 5 (0.402 ± 0.078)×106
4.1 636 2.42 0.259×106
4.2 647 2.37 0.250×106
4.3 640 2.71 0.258×106
4.4 621 2.48 0.268×106
mean value/uncertainty 636 ± 11 (0.259 ± 0.017)×106
5.1 425 3.13 0.165×106
5.2 442 3.50 0.167×106
5.3 443 1.82 0.145×106
5.4 428 4.00 0.160×106
mean value/uncertainty 434 ± 9 (0.160 ± 0.019)·106