Comparison between SCAPS-1D and wxAMPS software simulation results for CsSnCl3 PSCs.

Device structure Software Voc (V) Jsc (mA/cm2) FF (%) PCE (%)
ITO/PCBM/CsSnCl3/CBTS/Au SCAPS-1D 1.01 25.13 80.90 20.47
wxAMPS 0.99 16.79 80.92 13.52
ITO/TiO2/CsSnCl3/CBTS/Au SCAPS-1D 1.01 26.22 82.03 21.75
wxAMPS 1.01 21.25 82.23 17.68
ITO/ZnO/CsSnCl3/CBTS/Au SCAPS-1D 1.01 26.22 81.93 21.72
wxAMPS 1.00 20.26 80.83 16.46
ITO/C60/CsSnCl3/CBTS/Au SCAPS-1D 1.00 23.16 78.22 18.17
wxAMPS 0.99 17.15 80.94 13.84
ITO/IGZO/CsSnCl3/CBTS/Au SCAPS-1D 1.02 26.14 78.69 21.07
wxAMPS 1.02 21.51 79.84 17.47
ITO/WS2/CsSnCl3/CBTS/Au SCAPS-1D 1.01 25.92 81.33 21.32
wxAMPS 1.01 21.02 80.93 17.13