Table 1.
Test segmentation accuracy for 3D U-Net on all four myocardial chambers in terms of DSC.
| No. of Points | ||||
|---|---|---|---|---|
| LA | LV | RA | RV | |
| 10 | 0.776 ± 0.059 | 0.797 ± 0.06 | 0.744 ± 0.046 | 0.742 ± 0.053 |
| 15 | 0.811 ± 0.046 | 0.827 ± 0.038 | 0.783 ± 0.042 | 0.792 ± 0.043 |
| 20 | 0.836 ± 0.03 | 0.844 ± 0.036 | 0.816 ± 0.034 | 0.81 ± 0.034 |
| 30 | 0.851 ± 0.027 | 0.866 ± 0.023 | 0.846 ± 0.027 | 0.833 ± 0.026 |
| 50 | 0.886 ± 0.024 | 0.889 ± 0.017 | 0.869 ± 0.025 | 0.864 ± 0.021 |
| 100 | 0.917 ± 0.014 | 0.915 ± 0.013 | 0.9 ± 0.022 | 0.901 ± 0.016 |
| Average | 0.846 ± 0.059 | 0.857 ± 0.052 | 0.826 ± 0.062 | 0.824 ± 0.062 |