Skip to main content
. 2022 Oct 26;415(7):1265–1285. doi: 10.1007/s00216-022-04362-3

Table 1.

Performance summary of EV isolation techniques

Technique Separation property Throughput (μL/min) Recovery Purity Sample type
Ultracentrifugation Size, density Med Low
Precipitation Size, surface markers High Low Plasma and serum [7], urine [8]
SEC Size Med Med
Mechanical filtering Size 25–1000 Low–high Med–high Urine [18, 19], cell culture medium [1721], plasma and lung broncholalveolar lavage [17]
Functionalised surfaces Surface marker 0.05–14 Med High Cell culture medium [10, 24], urine [22], serum [11, 12, 23], plasma [10, 1425]
Hydrodynamic focusing Size 4.5–23 Med Med Plasma [28], cell culture medium [26, 27]
DLD Size < 15 Med Low Purified urine exosomes [30], serum [31], urine [31]
Viscoelastic separation Size 3 Med Low Purified cell culture media EVs [34, 36]
Acoustophoresis Size, density, compressibility 0.1–500 Low–high Med Whole blood [47], plasma [3841], urine [39, 42, 43], cell culture medium [38, 39, 45, 46]
Magnetophoresis Surface marker 0.8–3 Med–high High Whole blood [50], plasma [48], serum [13], cell culture medium [59], urine [59]
Dielectrophoresis Size, charge 3 Med–high Med Purified EVs [57, 58]