Skip to main content
. 2023 Feb 1;14:1107456. doi: 10.3389/fphys.2023.1107456

TABLE 2.

Mean (±SD) interaction and main effects for ultrasound derived superficial femoral artery measures pre and post low fat, high fat and high fat fidgeting sitting trials (n = 16).

Superficial femoral artery
Blood flow (ml·min) Shear rate (S−1) Avg. Diameter (mm) Velocity (cm·s−1) PWVß (m·s−1)
Mean average (SD)
Low Fat 0 min 314 (138) 39.9 (22.90) 6.73 (1.01) 15.0 (3.70) 5.72 (1.11)
180 min 287 (126) 31.8 (16.50) 6.67 (1.05) 15.2 (2.90) 6.32 (1.44)
High Fat 0 min 329 (106) 50.6 (29.70) 6.68 (0.98) 16.1 (4.40) 5.99 (1.65)
180 min 284 (98) 36.0 (31.20) 6.62 (1.03) 16.0 (4.50) 6.11 (1.06)
High Fat Fidget 0 min 340 (113) 43.0 (23.50) 6.76 (0.97) 16.8 (4.10) 5.76 (0.28)
180 min 360 (113) 49.7 (19.90) 6.77 (1.07) 17.1 (3.50) 6.29 (1.02)
Interaction Effect
p 0.043 0.032 0.814 0.825 0.516
Time Effect
p 0.118 0.109 0.465 0.623 0.026
Condition Effect
p <0.001 0.071 0.173 0.018 0.992

SD, standard deviation; m·s−1, meters per second; cm·s−1, centimetres per second; PWVß, pulse wave velocity beta; S−1, Shear; mm, millimetres; ml·min, millilitres per minute; min, minute.