Skip to main content
. 2023 Feb 15;14(2):509–526. doi: 10.1007/s13272-023-00644-3

Fig. 8.

Fig. 8

Experimentally recorded aerosol number–concentration (left) and volume aerosol concentration (right) on different seats during the course of one measurement run. Aerosol source started at t = 0 s; aerosol source stopped at dashed line. Aerosol source is located on seat 8E. Legend in the top applies for all images