. 2022 Sep 22;33(3):2075–2088. doi: 10.1007/s00330-022-09138-y

Table 1.

CT scanner information of the included studies

Study Country* Study design CT scanner Tube voltage/ Tube current Reconstruction slice thickness (mm) Window width, window level (HU)# Plain or enhanced CT Reconstruction algorithm
Takahashi et al, 2012 [17] Japan R

four-detector row scanners;

64-detector row scanner

140 kVp; 160–250 mAs -- 1500 or 1750, -600 or -700 Plain CT High-spatial-frequency algorithm
Chang et al, 2013 [18] Korea R

64-detector row scanners;

single-detector scanner

120 kVp; 40 mA < 2.5 1500, -700 Low-dose plain CT High-spatial-frequency algorithm
Kobayashi et al, 2013 [19] Japan R -- -- -- 1000 to 2000, -500 to -700 -- --
Lee et al, 2013 [20] Korea R

the Brilliance-64, MX-8000 IDT;

iCT 256

-- 1 or 3 1500, -600 -- --
Eguchi et al, 2014 [21] Japan R

Hispeed Advantage RP, Light Speed Ultra;

Light Speed VCT Vision

-- 1.25 1500, -550 Plain CT --
SHIN et al, 2014 [22] Korea R 64-detector row scanners 120 kVp; 20 mA 1.25 -- -- --
Kakinuma et al, 2015 [11] Japan P

16-row scanner;

64-row CT scanner

120 kVp; 30 mA 1 or 2 2000, -600 -- Standard reconstruction kernel (function kernel 01 or 03)
Cho et al, 2016 [7] Korea R the Brilliance-64, MX-8000 IDT,and iCT 256 -- 1 to 3 1500, -600 -- --
Sawada et al, 2016 [8] Japan R -- -- 1 -- Plain CT --
SATO et al, 2017 [10] Japan R Light Speed VCT or Optima CT 660 -- 0.625 to 2 1500, -650 -- --
Lee et al, 2019 [3] Korea R

16-slice detector CT scanner;

256-slice multidetector CT scanner

120 kVp, 30 mAs or 120 kVp, 20 mAs 1 or 3 1500, -600 Low-dose CT --
Qi et al, 2019 [23] China R

64-detector row scanners (LightSpeed VCT, Discovery CT750 HD or Optima CT660,

General Electric Medical Systems; TOSHIBA Aquilion,

TOSHIBA Medical Systems)

120 kVp,35 mAs or 120 kVp, 200–350 mAs 1 or 1.25 1600, -600 Low dose plain CT/ enhanced CT Standard reconstruction algorithm
Shi et al, 2019 [24] China R

Siemens, Somatom Definition AS scanner;

Philips, Brilliance 40 scanner

120 KVp; 200 mAs 1 1400, -450 Plain CT Standard soft kernel (Siemens B31 filter); sharp reconstruction kernel
Gao et al, 2020 [25] China R Siemens Somatom sensation, 64 slice, CT scanner 120 kVp; automatic tube currentmodulation 0.75 -- Plain CT Reconstruction kernel, B31f
Qiu et al, 2020 [26] China R

Discovery HD750-64;

LightSpeed VCT;

Somatom Definition Sensation-64;

Somatom Definition Flash Sensation-64

100–120 kVp, 200–280 mAs 0.625 to 1 1200, -600 -- --
Lee et al, 2020 [9] Korea R

Brilliance 64, Ingenuity, ICT 256, Mx 8000, Phillips Medical Systems;

Sensation 16, Somatom Definition, Siemens Medical Solutions;

Aquilion One, Toshiba;

Discovery CT 750 HD, Light Speed Ultra, GE Medical Systems

-- 1 to 5 -- Plain CT/ enhanced CT --

Note: R, retrospective; P, prospective; “‐‐”: not mentioned; *: country was based on the corresponding author; “#”: the lung window setting