Table 2.

Interobserver variance of the measured aortic diameters obtained by 3D-Dixon and 2D-SSFP MR-imaging as described by Bland and Altman

Interobserver variance
Sinuses of Valsalva Sinutubular junction Ascending aorta Mid aortic arch Descending aorta
3D-Dixon
Mean difference (mm) 0.53 0.57 1.00 0.40 0.15
Limit of agreements (mm) −2.81 to 3.87 −1.97 to 3.11 −2.19 to 4.19 −2.33 to 3.14 −3.04 to 3.34
Standard deviation (mm) 1.70 1.30 1.63 1.39 1.63
Variance (mm2) 2.91 1.69 2.65 1.94 2.65
Intraclass correlation coefficient (r) 0.98 0.98 0.98 0.94 0.94
2D-SSFP
Mean difference (mm) 0.38 0.13 0.87 −0.04 0.47
Limit of agreements (mm) − 2.09 to 2.85 −2.92 to 3.18 2.20 to 3.95 −2.81 to 2.73 −2.59 to 3.52
Standard deviation (mm) 1.26 1.56 1.57 1.41 1.56
Variance (mm2) 1.59 2.42 2.46 2.00 2.43
Intraclass correlation coefficient (r) 0.99 0.98 0.98 0.95 0.95
p value (t test) 0.55 0.88 0.66 0.15 0.21
p value (F test) 0.02 0.11 0.40 0.46 0.38

T-test was performed for comparison of mean differences and F-test for comparison of variances. Significant differences are in boldface (significant at p < 0.05)