Table 2.
PBF-LB parameters used in coupon fabrication of test specimens
| Laser power (W) | Hatch distance (μm) | Hatch offset (μm) | Layer thickness (μm) | Exposure time (μs) | Rotation increment angle (°) | Point distance (μm) |
|---|---|---|---|---|---|---|
| 400 | 100 | 50 | 60 | 60 | 67 | 80 |
PBF-LB parameters used in coupon fabrication of test specimens
| Laser power (W) | Hatch distance (μm) | Hatch offset (μm) | Layer thickness (μm) | Exposure time (μs) | Rotation increment angle (°) | Point distance (μm) |
|---|---|---|---|---|---|---|
| 400 | 100 | 50 | 60 | 60 | 67 | 80 |