Table 5. Indications for robotic living donor right hepatectomy proposed by Rho et al. (63).
| Variables | Initial indications | Final indications |
|---|---|---|
| Right hepatic artery | One hepatic artery | No variation |
| Common length >1 cm | ||
| Right portal vein | Common length >1 cm | Common length >1 cm |
| Some variants are acceptable | ||
| Right bile duct | Common length >0.5 cm | Common length >0.5 cm |
| Some variants are acceptable | ||
| Right inferior hepatic vein | No inferior RIHV | No limitation |
| Middle hepatic vein branch (V5 and V8) | No limitation | No limitation |
| Estimated graft volume | <800 g | <1,000 g |
RIHV, right inferior hepatic vein.