Skip to main content
. 2023 Feb 8;13:1076525. doi: 10.3389/fcimb.2023.1076525

Table 2.

Comparison of positive rate between mNGS and traditional detection methods.

Test methods Positive Negative Total Positive rate (%) X 2 value P-value
mNGS 80 12 92 86.96
culture 18 74 92 19.57 83.92 0.000*
PCT 18 36 54 30.33 44.34 0.000*
WBC 16 76 92 17.39 89.21 0.000*
IGRAs 27 43 70 38.57 41.50 0.000*

* indicates that Pearson's chi-square test was used to compare the sensitivity between mNGS and other traditional detection methods. Positive PCT and WBC indicate increased PCT levels and WBC count; negative PCT and WBC indicate normal PCT levels and WBC count.