Skip to main content
. 2023 Feb 22;14:989. doi: 10.1038/s41467-023-36645-3

Fig. 3. Measurements of the manufactured DPM.

Fig. 3

a The far-field experimental setup in an anechoic chamber. b Photographs of the fabricated prototype. c Zynq-7000 SoC series FPGA for voltage control. d The measured far-field patterns when beams on the E-plane vary from −40° to 40° at 5.8 GHz. These experiments verify that the DPM can shape the far-field patterns in the spatial domain by configuring the digital codes.