Skip to main content
. 2023 Feb 23;43(5):921–932. doi: 10.1007/s10875-023-01451-5

Table 2.

Flow cytometry of lymphocyte subsets in peripheral blood, serum immunoglobulins, and specific antibodies

Patient 1* Patient 2 Patient 3* Ref. values for age**
WBC (cells/µL) 7,645 NR 6,270 5,900 (4,600–7,100)
Lymphocytes (%) 20 NR 30.2 32 (28–39)
Lymphocytes (cells/ µ L) 1,529 NR 1,894 2,300 (1,200–4,100)
Lymphocyte subsets
  CD3+ (%) 56 NR 71.7 67 (50–91)
  CD3+(cells/µL) 856 876 (700–2,100) 1,358 1,500 (780–3,000)
  CD3+/CD4+ (%) 36.2 NR 44.3 42 (28–64)
  CD3+/CD4+ (cells/µL) 553 613 (300–1,400) 839 1,000 (500–2,000)
  CD3+/CD8+ (%) 18.7 NR 23.5 22 (12–40)
  CD3+/CD8+ (cells/µL) 286 265 (200–900) 445 500 (200–1,200)
  CD3+/CD4+/CD8+ (%) 0.4 NR 0.4 0.26 (0.08–0.94)
  CD3+/CD4+/CD8+ (cells/µL) 4 NR 6 12 (2–60)
  CD4/CD8 ratio 1.9 2.3 1.9 1.9 (1.0–3.6)
  CD19+ (%) 13.4 NR 8.5 10 (4–28)
  CD19+ (cells/µL) 205 NR 161 230 (64–820)
  CD3CD16+/CD56+ (%) 24.1 NR 16.5 15 (5–49)
  CD3-CD16+/CD56+ 368 NR 312 340 (100–1,200)
  CD45+/CD14+ (%) 7.7 NR 5.7 3–8
  CD45+/CD14+ /µL 591 NR 359 100–8,000
Serum immunoglobulins
  IgG (mg/dL) 1467 (540–1,822) 1098 ND (814–2,047)
  IgA (mg/dL) 200 (63–484) 88 ND (81–538)
  IgM (mg/dL) 213 (22–240) 154 ND (42–600)
  IgE (IU/mL) 1,151 (0–100) ND ND
  HB IgG (mU/mL) 0.08 (< 10) ND ND
  Rubella IgG (mU/mL) 187 (< 10) ND ND

Values in bold are outside the normal ranges for age

ND not done, NR not reported

*Flow cytometry of lymphocyte populations performed on peripheral blood lymphocytes (PBLs) stained with fluorochrome-labeled mAbs. Cells were collected on a FACS Canto II (BD Biosciences, San José, CA), and the data were analyzed with FlowJo v8.2 (TreeStar, Ashland, OR) by gating on CD45+ leukocytes. Reference values for lymphocyte subsets from Schatorjé EJH, et al. Scand. J Immunol. 2012 vol. 75 (4) pp. 436–44

**For patient 2, only results from the BD Tritest™ (BD Biosciences) were available and reference values are as indicated in the hospital records