Skip to main content
. 2023 Feb 7;62(7):3282–3293. doi: 10.1021/acs.iecr.2c03722

Table 3. Parameters Obtained from the Fitting of Happ,j to eq 13a.

  a b c d E f R2 F-value p-value
CB 2.54 –0.24 0.08 8.52 × 103 –4.39 × 104 6.90 × 105 0.99 349 4.42 × 1019
1,4-DCB 0.26 –0.34 0.11 1.35 × 102 –7.73 × 104 –3.68 × 104 0.97 173 6.77 × 1017
1,2-DCB 0.16 –0.37 0.13 1.44 × 102 –9.25 × 104 –4.64 × 105 0.97 136 1.09 × 1017
1,2,4-TCB –3.94 –0.37 0.26 1.84 × 102 –2.03 × 103 –2.36 × 103 0.97 408 1.08 × 1015
1,2,3-TCB –4.69 –0.37 0.26 1.69 × 102 –1.98 × 103 –2.08 × 103 0.98 171 4.61 × 1019
a-TetraCB –5.28 –0.60 0.27 2.63 × 102 –2.19 × 103 1.04 × 104 0.98 320 1.82 × 1020
b-TetraCB –6.05 –0.57 0.28 2.60 × 102 –2.17 × 103 –4.11 × 104 0.98 325 1.53 × 1020
a

The statistical parameters were obtained from variance analysis. The coefficient of variation (R2), Fischer’s test value (F-value), and probability (p-value) are also shown.