Percentage of undetected lesions for each sequence and b-value combination.

Sequence b1500 b2000 b2500
z-DWI 6.1% 13.6% 18.4%
IR m-b1500 DWI 4.1% 6.8% 11.6%
s-DWI 8.2% 13.6% 17.7%

DWI: diffusion-weighted imaging; s-DWI: single-shot echo-planar DWI sequence; z-DWI: zoomed DWI with spectral-attenuated inversion-recovery fat saturation; IR m-b1500 DWI: DWI with improved inversion-recovery fat saturation and measured b1500.