Table 3.
Subgroup analysis of the RTKA failure patterns including only full-cemented RTKA stems, divided into Co, Cy and Combi stem profiles
Conical (Co) |
Cylindrical (Cy) |
Combination (Combi) |
All | Sign Co vs. Cy |
|
---|---|---|---|---|---|
All components | 36 | 58 | 6 | 100 | |
All cemented components | 36 | 50 | 2 | 88 | 0.02 |
Removed cemented components | |||||
All | 35 | 45 | 2 | 82 | 0.19 |
f | 17 | 23 | 1 | 41 | |
t | 18 | 22 | 1 | 41 | |
Causes of removed cemented implants | |||||
PJI | 20 | 23 | 2 | 45 | 0.59 |
Aseptic loosening | 9 | 21 | 0 | 30 | 0.05* |
Malposition | 4 | 1 | 0 | 5 | 0.09 |
Instability | 2 | 0 | 0 | 2 | 0.10 |
Co conical stem design, Cy cylindrical stem design, Combi combined stem designs, RTKA revision total knee arthroplasty, Re-RTKA Re-revision, PJI periprosthetic joint infection, f femoral, t tibial
*Differences are significant at the 0.05 level