Skip to main content
. 2023 Feb 6;12(4):1297. doi: 10.3390/jcm12041297

Table 3.

Comparison of manual measurement and AI automatic measurement (paired samples t-test).

Features The Difference of Manual
and AI Automatic Measurement
AI Automatic Measurement Manual
Measurement
Mean Test Statistic t 95% CI of Difference Sig. Mean ± SD Mean ± SD
MPAd (mm) −2.249 −3.573 −3.511 to −0.9874 0.001 34.48 ± 3.98 36.73 ± 5.98
RPAd (mm) −0.5759 1.222 −0.3693 to 1.521 0.227 24.33 ± 3.01 23.75 ± 3.82
LPAd (mm) 2.843 4.394 1.546 to 4.140 0.000 25.42 ± 4.61 22.57 ± 3.73
AAd (mm) −0.1506 −0.347 −1.020 to 0.718 0.730 29.81 ± 4.61 29.96 ± 5.57
LVd (mm) 4.975 4.255 2.632 to 7.319 0.000 39.78 ± 8.51 34.80 ± 9.66
RVd (mm) 0.5214 0.484 −1.636 to 2.679 0.630 44.39 ± 5.62 43.87 ± 9.32
LAd (mm) −0.2745 −0.320 −1.994 to 1.445 0.750 29.60 ± 6.52 29.88 ± 9.06
RAd (mm) −11.68 −7.096 −14.98 to −8.382 0.000 46.47 ± 7.49 58.15 ± 15.15

Note. AAd, diameter of ascending aorta; LAd, diameter of left atrium; LPAd, diameter of left pulmonary artery; LVd, diameter of left ventricle; MPAd, diameter of main pulmonary artery; RAd, diameter of right atrium; RPAd, diameter of right pulmonary artery; RVd, diameter of right ventricle.