The evaluation indicators of four ML models under 11 classifiers (mean ± standard deviation).

Models Training AUC Testing AUC Accuracy Precision Recall F1
DVH 0.804 ± 0.053 0.801 ± 0.06 0.751 ± 0.068 0.738 ± 0.067 0.783 ± 0.16 0.751 ± 0.095
Radio + DVH 0.856 ± 0.044 0.805 ± 0.046 0.809 ± 0.062 0.772 ± 0.066 0.886 ± 0.118 0.821 ± 0.067
Radio + dose 0.833 ± 0.041 0.801 ± 0.057 0.806 ± 0.048 0.756 ± 0.045 0.911 ± 0.128 0.821 ± 0.061
Radio + eqdose 0.900 ± 0.033 0.799 ± 0.050 0.856 ± 0.034 0.809 ± 0.070 0.950 ± 0.059 0.870 ± 0.024