Table 2.
Models | Training AUC | Testing AUC | Accuracy | Precision | Recall | F1 |
---|---|---|---|---|---|---|
DVH | 0.804 ± 0.053 | 0.801 ± 0.06 | 0.751 ± 0.068 | 0.738 ± 0.067 | 0.783 ± 0.16 | 0.751 ± 0.095 |
Radio + DVH | 0.856 ± 0.044 | 0.805 ± 0.046 | 0.809 ± 0.062 | 0.772 ± 0.066 | 0.886 ± 0.118 | 0.821 ± 0.067 |
Radio + dose | 0.833 ± 0.041 | 0.801 ± 0.057 | 0.806 ± 0.048 | 0.756 ± 0.045 | 0.911 ± 0.128 | 0.821 ± 0.061 |
Radio + eqdose | 0.900 ± 0.033 | 0.799 ± 0.050 | 0.856 ± 0.034 | 0.809 ± 0.070 | 0.950 ± 0.059 | 0.870 ± 0.024 |