Skip to main content
. 2022 Dec 8;97(3):769–785. doi: 10.1007/s00204-022-03425-9

Table 4.

Receiver operating characteristics (ROC) curve analyses

CPA1 CPA2 TAP amylase lipase miR217
Correlated to pancreatic injury
 2. A Sensitivity studies only. All time-points (103 control, 132 treated) AUC 0.79 0.72 0.81 0.67 0.77 0.87
sensitivity 64% 43% 69% 50% 50% 75%
cut-off N/A N/A 2 1.3 1.3 N/A
 2. B Sensitivity studies only ≤ 3 days (55 controls, 87 treated) AUC 0.9 0.82 0.97 0.68 0.80 0.97
sensitivity 86% 63% 90% 53% 57% 95%
cut-off N/A N/A 2.2 1.4 0.3 N/A
 2. C Sensitivity and specificity studies. All time-points. 2.A sample set with added specificity samples (40 controls and 68 treated) AUC 0.78 0.72 0.80 0.63 0.75 0.87
sensitivity 64 % 43% 70% 48% 46% 75%
cut-off N/A N/A 2 1.4 1.5 N/A
Correlated to treatment with pancreatic toxicant, 4-6 hrs post-dose
 2. D Sensitivity studies 4-6 hours post-dose with controls ≤ 3 days (57 controls, 37 treated) AUC 0.90 0.88 0.89 0.86 0.95 0.81
sensitivity 76% 76% 76% 76% 76% 59%
cut-off N/A N/A 1.9 1.4 1.3 N/A