Skip to main content
. 2023 Feb 13;5:1106882. doi: 10.3389/fspor.2023.1106882

Table 1.

Environmental conditions at the end of outdoor exercise and during indoor recovery periods.

Outdoor (Exercise) Indoor (Recovery)
CON FAN P CON FAN P
Global solar radiation (W/m2) 1,101 ± 40 1,107 ± 22 0.812
Mean radiant temperature (°C) 67.9 ± 6.8 68.5 ± 5.5 0.812
Ambient temperature (°C) 32.9 ± 1.8 33.1 ± 1.8 0.675 30.0 ± 1.7 30.1 ± 1.8 0.905
Relative humidity (%) 50.0 ± 8.0 49.9 ± 8.1 0.812 57.6 ± 6.9 57.2 ± 7.1 1.000
Air velocity (m/sec) 0.8 ± 0.3 0.8 ± 0.3 0.858 0.1 ± 0.1 0.1 ± 0.1 1.000
WBGT (°C) 30.0 ± 0.9 30.2 ± 1.0 0.311 26.6 ± 0.7 26.6 ± 0.8 0.858

Values are means ± SD. CON, no-cooling condition; FAN, wearing fan-cooling jacket; WBGT, wet-buld globe temperature.