Table 4.
Prosthesis-related mechanical complications of patients in the included studies.
Study | Mechanical complications | Hypothyroid group, n (%) | Control group, n (%) | OR | 95% CI | P-value |
---|---|---|---|---|---|---|
Jing et al. (14) | Peri-prosthetic fracture | 1 (0.3) | 0 (0) | 1.00 | 0.95–1.05 | 0.317 |
Buller et al. (7) | ||||||
Aseptic loosening | 69 (0.07) | 60 (0.06) | 1.119 | 0.787–1.590 | 0.531 | |
Dislocation | 453 (0.46) | 355 (0.36) | 1.258 | 1.095–1.446 | 0.01 | |
Broken implant | 20 (0.02) | 20 (0.02) | 1.05 | 0.569–1.937 | 0.876 | |
Peri-prosthetic fracture | 177 (0.18) | 148 (0.15) | 1.153 | 0.927–1.434 | 0.202 | |
Other | 60 (0.06) | 39 (0.04) | 1.6 | 1.078–2.376 | 0.019 | |
Yuan et al. (16) | Aseptic loosening | 0 (0) | 0 (0) | N/A | N/A | 1 |