Diagnostic accuracy of two manual anterior drawer tests by the senior and junior examiners

Sensitivity (95% CI) Specificity (95% CI) PPV (95% CI) NPV (95% CI) κ
Traditional ADT Junior examiner 0.400 (0.122–0.738) 0.750 (0.509–0.913) 0.444 (0.137–0.788) 0.714 (0.478–0.887) 0.416 (0.096–0.735)
Senior examiner 0.800 (0.444–0.975) 0.600 (0.361–0.809) 0.500 (0.247–0.753) 0.857 (0.572–0.982)
Supported ADT Junior examiner 0.800 (0.444–0.975) 0.800 (0.563–0.943) 0.667 (0.349–0.901) 0.889 (0.653–0.986) 0.571 (0.265–0.878)
Senior examiner 0.700 (0.348–0.933) 0.850 (0.621–0.968) 0.850 (0.621–0.968) 0.722 (0.465–0.903)

Data are presented as mean (range), unless otherwise noted