Table 2.

Results of 1-year AF recurrence prediction

AUROC Sensitivity Specificity Accuracy F1-Score
APPLE Score 0.644 ± 0.129 0.915 ± 0.138 0.350 ± 0.329 0.504 ± 0.213 0.533 ± 0.111
CHA2DS2-VASc Score 0.650 ± 0.133 0.905 ± 0.162 0.427 ± 0.355 0.560 ± 0.226 0.568 ± 0.124
Clinical Feature 0.755 ± 0.093 0.875 ± 0.137 0.680 ± 0.198 0.728 ± 0.121 0.656 ± 0.102
EGM 0.731 ± 0.105 0.885 ± 0.116 0.627 ± 0.131 0.701 ± 0.098 0.630 ± 0.092
ECG 0.767 ± 0.122 0.812 ± 0.176 0.770 ± 0.183 0.781 ± 0.112 0.682 ± 0.108
Fusion of EGM & Clinical Data 0.788 ± 0.110 0.905 ± 0.117 0.706 ± 0.144 0.764 ± 0.107 0.691 ± 0.117
Fusion of ECG & Clinical Data 0.836 ± 0.063 0.865 ± 0.112 0.812 ± 0.124 0.827 ± 0.070 0.747 ± 0.075
Fusion of EGM & ECG 0.833 ± 0.084 0.915 ± 0.138 0.793 ± 0.124 0.826 ± 0.083 0.753 ± 0.096
Fusion of EGM, ECG & Clinical Feature 0.859 ± 0.082 0.870 ± 0.200 0.867 ± 0.121 0.866 ± 0.076 0.784 ± 0.106

Values are mean ± standard deviation across 10-folds. Best mean results for each metric are highlighted in bold.