Skip to main content
. 2023 Jan 20;51(4):1674–1686. doi: 10.1093/nar/gkac1274

Table 1.

Biophysical parameters derived from SAXS and MALS data

Instrument = ALS beamline 12.3.1; q range = 0.01–0.35 (Å−1); exposure time = 3 s; temperature = 20°C
Parameters Full length (FL) NT + ZF ZF + CT DNA
No DNA + DNA No DNA + DNA No DNA + DNA
Concentration (mg/ml) 4 4 5 5 13 13 5
(μM) ∼77 ∼124 ∼448 ∼454
MW (kDa) Calculated (monomer) 52 63 40 51 29 40 11.1
SEC-MALS 56 63 46 52 33 40 11.2
SAXS MoW 55.9 64 43.7 53.8 31.7 38.1 10.8
Porod volume (Å3) 105 839 117 525 78 713 94 146 55 180 70 985 15 604
D max (Å) 122 142 107 141 95 119 58
Low-q range (Å−1) used for Guinier analysis 0.02–0.04 0.02–0.03 0.01–0.05 0.01–0.03 0.02–0.05 0.01–0.04 0.02–0.07
I(0) (Å) from Guinier 8.41 21.81 4.72 30.28 9.79 130.50 25.90
from P(r) 8.41 21.81 4.72 30.28 9.78 130.50 25.91
R g (Å) from Guinier 38.54 43.80 31.95 40.60 29.71 30.72 18.33
from P(r) 38.69 43.85 31.11 40.62 29.71 30.89 18.38

Values of Rg and I(0) parameters were estimated from Guinier plot and P(r) plot analyses.