Matrix study: 3M Petrifilm RYM Plate 25°C at 72 h versus DRBC—difference of means

Matrix Contamination level 3M Petrifilm RYM Plate, 25°C; 72 h
DRBC
DOMd SEe 90% CIa
95% CI
Meanb src Mean sr LCLf UCLg LCL UCL
Cannabis Flowerh Low 3.281 0.094 3.688 0.218 −0.407 0.106 −0.577 −0.236 −0.629 −0.185
Med 3.816 0.042 3.906 0.047 −0.09 0.028 −0.12 −0.06 −0.129 −0.051
High 5.139 0.063 5.145 0.204 −0.005 0.064 0.143 0.132 −0.184 0.174
Cannabis Floweri Low 2.850 0.222 3.151 0.211 −0.301 0.121 −0.468 0.047 −0.403 −0.199
High 5.435 0.180 5.539 0.143 −0.105 0.075 −0.264 0.055 −0.379 −0.222
a

CI = Confidence interval for DOM.

b

Mean of five replicate portions, after logarithmic transformation: log10[cfu/g + (0.1)f] where f is the smallest reportable result.

c

Repeatability standard deviation.

d

DOM = Difference of means.

e

Standard error of the mean difference for paired analysis.

f

LCL = Lower confidence limit for DOM.

g

UCL = Upper confidence limit for DOM.