The agreement between automatic and visual scoring from CSCT scans and manual, automatic, and visual scoring from LDCT scans with a gold standard

CSCT LDCT
Automatic Visual Manual Automatic Visual
Weighted linear κ 0.95 0.88 0.59 0.50 0.82
95% CI 0.92–0.97 0.85–0.92 0.53–0.65 0.44–0.56 0.77–0.87
% of cases within the same category 91.0 82.1 35.2 29.5 74.2
% of cases within 1 category below or above the correct one 100 100 94.3 93.6 98.1
% of cases incorrectly assigned as 0 Agatston score 0.9 0 4.2 12.7 3.2