Skip to main content
. 2023 Feb 2;26(3):106121. doi: 10.1016/j.isci.2023.106121
REAGENT or RESOURCE SOURCE IDENTIFIER
Biological samples

hiPSC-CMs Ncardia Pluricyte® Cardiomyocyte, PCMI-1033-1
hiPSC-CMs Humanitas Clinical and Research Center-IRCCS See “Experimental Model and subject details” section for the differentiation protocol.

Chemicals, peptides, and recombinant proteins

Fura-2-AM Thermofisher Scientific F1201
hiPSC growth medium Thermofisher Scientific StemFlex Medium (A3349401)
Vitronectin (VTN-N) Recombinant Human Protein, Truncated Thermofisher Scientific A14700
hiPSC-CMs medium Ncardia Pluricyte® Cardiomyocyte Medium, PM-2100-100mL
B27-Supplement w/o insulin Thermofisher Scientific 0050129SA
B27-Supplement Thermofisher Scientific 17504044
Growth Factor-Reduced Matrigel (10ml) BD Biosciences 354230
RPMI Medium 1640 with L-Glutamine Thermofisher Scientific 11875-119
CHIR-99021 Selleckchem S1263-5MG
IWR1 Sigma Aldrich 10161-5MG
Y-27632 (ROCK Inhibitor) Selleckchem S1049
Laminin Sigma Aldrich L2020
Fibronectin Sigma Aldrich F0895-2MG

Software and algorithms

Microsoft Excel Microsoft https://www.microsoft.com/
GraphPad Prism Prism https://www.graphpad.com/
MATLAB MathWorks https://it.mathworks.com/
Origin 9.0 OriginLab Corporation https://www.originlab.com/
pClamp-10 software Axon Instruments http://go.moleculardevices.com/
Contraction analysis code This paper [GitHub]: [https://github.com/BeatriceFederici/contraction_tracking.git]

Other

Patch-Clamp Amplifier Molecular Devices Axopatch 200B
Patch-Clamp Amplifier Molecular Devices MultiClamp 700B
Analog to digital converter Molecular Devices Digidata 1440A
Microscope Nikon Eclipse Ti
Microscope Nikon Eclipse TE200
Illumination source Lumencor Spectra X
Illumination source Cairn Research Arc Lamp Light Source coupled with high-speed OptoScan monochromator
Camera Photometrics Prime 95B Scientific CMOS (sCMOS) Camera
Camera ThorLabs
CS135MUN, Kiralux 1.3 MP NIR-Enhanced CMOS Camera