Skip to main content
. 2023 Mar 10;13(12):8000–8014. doi: 10.1039/d3ra00712j

Intensity ratios for several specimens before and after a wear test under different testing conditions.

Compound and conditionsa Position on the sample R b
C-0 (2.4 wt% CNT) Pristine 1.65
Wear trace 1.51
C-3 (2.4 wt% CNT and 2.5 wt% IL) Pristine 1.27
Wear trace 1.39
C-3 (2.4 wt% CNT and 2.5 wt% IL) after wear test with applied potential Pristine 1.47
Wear trace 1.46
E-0 (2.4 wt% CB) Pristine 1.90
Wear trace 1.80
E-3 (2.4 wt% CB and 2.5 wt% IL) Pristine 1.85
Wear trace 1.95
E-3 (2.4 wt% CB and 2.5 wt% IL) after wear test with applied potential Pristine 1.87
Wear trace 1.91
a

If not stated otherwise the tribological testing was performed without applied potential with a ball on plate geometry.

b

All fits spectra were fitted until a coefficient of determination R2 > 0.99 was reached.