CONFIGURATION INFORMATION ========================= Path : /opt/topspin3.6.1/conf/instr/spect/uxnmr.info Date : Mon Feb 18 16:58:12 2019 Release : TopSpin 3.6.1 Installed in : /opt/topspin3.6.1 Host : rsav600mb OS : CentOS Linux release 7.6.1810 (Core) CPU : Intel(R) Xeon(R) CPU E5-1620 0 @ 3.60GHz (8 cores at 1970 MHz with Hyperthreading) User : tstrat (Thomas Stratton) System : Avance III HD 600 NMR spectrometer 1H-frequency : 600.14 MHz Description : AVHD 600 Location : Scripps Research Institute La Jolla Bruker Order : 10100787 Configured in: rsav600mb:/opt/topspin3.6.1/conf/instr/spect IPSO: connected to spectrometer subnet - TCP/IP address = 149.236.99.90 - IPSO type: AQS - Tctrl : 1 - Fctrls: 2 - Gctrl1: without digital preemphasis - Rctrl : 1 - FREDs : none - DPP : none DRU1: AQS DRU-E Z102520/03563 ECL 07.00 - TCP/IP address = 149.236.99.89 - Firmware Version = 170619 - DRU1 controls AQS-Rack and HPPR/2 AQS: connected to 149.236.99.89:/dev/tty10 _Slot_ SBSB _____________________Board_____________________ Number Addr Type HW-VS FW-VS ID ECL Name Description ----------------------------------------------------------- 2 0x10 0x43 0x5 CD R 0.2 REC-1 AQS RXAD/2 600 Z130588/806 ECL 00.02 3 0x34 0xd6 0x1 X 3.0 REF-1 REF/3-600 Reference Board for AQS/3 Receiver 4 0x24 0x32 0 S 2.2 SGU-1 AQS SGU/3 600 (2CH) Z117129/01008 ECL 02.02 FPGA-Vs=20131031 13 0xa0 0x93 0 V 0.1 PS-1 14 0xa1 0x91 0 V 1.2 PS-2 AQS PSM-D Power Supply Module -- 0x20 0xd8 0 B 1.1 MASTER AQS/3+ Chassis 1 0x20 0x7 0 B MASTER AQS Rack Master Logical Receiver/SGU configuration: Router: none installed Transmitters at the spectrometer subnet: ---------------------------------------- BLA_W1345083_0701 W1345083/0701 ECL 21: - TCP/IP address = 149.236.99.92 - Firmware VS = 20120627 - Amplifier = BLAXH300/100 E 200-600MHZ INR: W1345083/0701 ECL 21 - Router = BLMMR32 RF AMPLIFIER MODULE: W1345204/1528 ECL 20 - Controller = BLA CONTROL BOARD 6 2CH: W1522050/7578 ECL 50 - QNP-Accessory : 1 X-input and 1 H-input LTRX Z109890/00431 ECL 03.01: - TCP/IP address = 149.236.99.20 - Amplifier = BSMS/2 LOCK TRANSCEIVER 600: Z109890/00431 ECL 03.01 BSMS: BSMS/2 connected to ethernet - TCP/IP address = 149.236.99.20 - ELCB firmware version = 20150130 - GAB current limits = 0.0/X, 0.0/Y, 10.0/Z (in A) - SCB channels = 40 - Shim System = BOSS3-SB - L-TRX = BSMS/2 LOCK TRANSCEIVER 600: Z109890/00431 ECL 03.01 - Lock: on L-TRX board - VTU_SPB = BSMS/2 SPB SENSOR & PNEUMATIC BD: Z115191/01616 ECL 04.00 - VTU_VPSB1 = BSMS/2 VARIABLE POWER SUPPLY BD: Z115193/01816 ECL 01.05 VTU: in BSMS/2 connected to ethernet - TCP/IP address = 149.236.99.20 Cryo Controller CRCO: device connected to 149.236.99.90:/dev/tty04 Preamplifiers : HPPR2: - HPPR/2 preamplifier connected to 149.236.99.89:/dev/tty10 Type : HPPR/2 Controller: Cover/2, with DRU Application firmware = c. no LED display for tuning and matching Module 1 : HPLNA 19F1H (virtual 50 Ohm reference: 100.0%/0.0deg, reflection meter) PN=Z103205, SN=00257 from 20130828 Module 2 : 2H PN=Z003473, SN=01064 from 20130910 Module 3 : XBB19F 2HS PN=Z003506, SN=01262 from 20130917 Module 4 : QNP Function Module Gradient Controller cable connections -------------------------------------------------------------------- GCtrl1: connected to GAB in BSMS RF cable connections (detected) -------------------------------------------------------------------- SGU1 NORM output -> input 1 of transmitter 1 (BLAXH300/100 E 200-600MHZ INR W1345083/0701 at TCP/IP 149.236.99.92) SGU1 AUX output -> input 1 of transmitter 2 (BSMS/2 LOCK TRANSCEIVER 600 Z109890/00431 at TCP/IP 149.236.99.20) SGU2 NORM output -> input 2 of transmitter 1 (BLAXH300/100 E 200-600MHZ INR W1345083/0701 at TCP/IP 149.236.99.92) SGU2 AUX output -> TUNE signal input of HPPR Blanking cable connections (detected) -------------------------------------------------------------------- transmitter 1 = BLAXH300/100 E 200-600MHZ INR W1345083/0701 at TCP/IP 149.236.99.92: - amplifier 1H-100W uses blanking 2 - amplifier X-300W uses blanking 1 transmitter 2 = BSMS/2 LOCK TRANSCEIVER 600 Z109890/00431 at TCP/IP 149.236.99.20: - amplifier 2H-5W uses blanking 7 Switchbox (3 outputs: X / F / H) routing -------------------------------------------------------------------- transmitter 1 = BLAXH300/100 E 200-600MHZ INR W1345083/0701 at TCP/IP 149.236.99.92: - amplifier X-300W at blanking 1 can be routed to switchbox output 1 = X and output 2 = F - amplifier 1H-100W at blanking 2 can be routed to switchbox output 1 = X, output 2 = F and output 3 = H