Skip to main content
. Author manuscript; available in PMC: 2017 Apr 10.
Published in final edited form as: Europace. 2016 Dec;18(Suppl 4):iv121–iv129. doi: 10.1093/europace/euw369

Table 1. Patient characteristics from MRI, ECG and invasive catheter pressure recordings including end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), heart rate (HR), QRS duration and the maximum rate of rise of pressure (dP/dt)max.

Sex Age (years) Disease EDV (mL) ESV (mL) EF (%) HR (1/min) QRS (ms) (dP/dt)max (mmHg/ms)
Case 1   F   9 CoA   67.9 22.1 67.5 64.1   90 1.97
Case 2 M 15 AVD 199.6 50.0 74.9 80.7 171
Case 3 M 10 CoA   81.9 21.8 73.4 92.6 104 2.66
Case 4 M 15 CoA 111.2 29.8 73.2 89.3   88 2.20

Note that AVD patients were not catheterized and as such no pressure recordings are available.