Skip to main content
. Author manuscript; available in PMC: 2018 Dec 21.
Published in final edited form as: Biostatistics. 2019 Jan 1;20(1):1–16. doi: 10.1093/biostatistics/kxx058

Table 2. RR of hospital admission: PM10 higher than 25 μg/m3 (chosen cut point) in Greater London. The main analysis with ≥5 subjects per wards is presented in bold, while the others are used as sensitivity analyses.

Areas Data used ≥1 subject
(12.9% missing)
≥5 subjects
(24.6% missing)
≥10 subjects
(37.4% missing)
≥20 subjects
(68.0% missing)
RR
95% CI
(95% CI)
width
RR
95% CI
(95% CI)
width
RR
95% CI
(95% CI)
width
RR
95% CI
(95% CI)
width
iS X,C 0.91
(0.86–0.96)
0.10 0.94
(0.89–1.00)
0.11 0.96
(0.90–1.03)
0.13 0.96
(0.88–1.04)
0.16
X,C,EPS 1.04
(0.94–1.14)
0.10 1.06
(1.01–1.12)
0.12 1.07
(1.01–1.15)
0.14 1.05
(0.95–1.16)
0.21
iSI X,C 0.89
(0.84–0.94)
0.10 0.89
(0.84–0.94)
0.10 0.89
(0.84–0.94)
0.10 0.89
(0.84–0.94)
0.10
X,C,EPS 1.05
(0.99–1.12)
0.13 1.02
(0.96–1.09)
0.13 1.03
(0.97–1.10)
0.13 1.06
(0.99–1.13)
0.14
X,C,M
(MICE)
0.98
(0.93–1.04)
0.11 0.93
(0.88–0.99)
0.11 0.92
(0.87–0.98)
0.11 0.89
(0.84–0.94)
0.10