Table 1.
Abdomen and Control Brain |
Control Brain only |
|||
---|---|---|---|---|
Description | HT2W volume | SST2W stack | BFFE volume | HR T2W volume |
Acquisition Type | 3D | 2D | 3D | 3D |
Repetition Time [ms] | 1120 | 1161 | 2.46 | 2500 |
Echo Time [ms] | 662.00 | 80.00 | 1.23 | 252.83 |
Flip Angle [◦] | 90 | 90 | 15 | 90 |
Pixel Spacing [mm] | 0.65 × 0.65 | 0.78 × 0.78 | 0.73 × 0.73 | 0.98 × 0.98 |
Slice Thickness [mm] | 1.8 | 5 | 1.5 | 1 |
Slice Spacing [mm] | 0.9 | 5 | 1.5 | 0.5 |
Number of Slices | 90 | 20‐25 | 83 | 360 |
Abdominal Imaging Trigger | Respiratory bellow | Expiratory BH | Expiratory BH | ‐ |
Abdominal Scan Duration | 04:06.0 | 00:21.5‐00:33.3 | 00:23.0 | ‐ |
Notes: For the abdominal imaging, the heavily T2-weighted (HT2W) volume is acquired as a gated acquisition triggered by a respiratory bellow. The single-shot T2-weighted (SST2W) stack and the balanced fast field echo (BFFE) acquisitions are acquired at separate expiratory breath-holds (BH). For the quasi‐static control brain experiment, no imaging trigger is used and an additional HR T2W volume is acquired for ground-truth comparisons. Example images associated with this protocol are shown in Figure 2.