Table 2.

Lung volumes in both lung states for all patients. The lung volume in the deep inspiration breath hold state (VDIBH) is much greater than that in the end of exhalation state (VEE).

Patient No. VDIBH (cc) VEE(cc) Absolute difference
|VDIBHVEE| (cc)
Volume ratio
VDIBH/VEE

1 6021.8 3643.8 2378.0 1.65
2 6351.3 3459.7 2891.6 1.84
3 7391.8 3734.5 3657.3 1.98
4 5508.5 3397.3 2111.2 1.62
5 4460.3 2807.9 1652.4 1.59
6 5287.1 3109.8 2177.3 1.70
7 6246.5 4214.8 2031.7 1.48
8 7311.1 6055.4 1255.7 1.21
9 3428.8 2637.0 791.8 1.30
10 6814.6 4959.1 1855.5 1.37
11 4877.4 3222.3 1655.1 1.51
12 4066.6 2591.9 1474.7 1.57
13 4802.7 2518.3 2284.4 1.91
14 5514.1 3091.7 2422.4 1.78
Mean ± standard deviation 5577.3 ± 1189.8 3531.7 ± 986.5 2045.7 ± 707.6 1.61 ± 0.22