Lymphocyte enumeration in blood by flow cytometry (Day of life (DOL), hospital day (HD) and post-transplant day (T)) (note: absolute lymphocyte counts for flow cytometry were calculated on separate samples than CBC with differential from same day, thus slight differences exist between data in this table and supplemental table 1).

DOL 28 DOL 53 DOL 83 (HD#4) DOL 104 (HD#25) DOL 154 (T +47) Reference range
Absolute Lymphocyte Count (/ul) 977 1271 1510 2512 3920
CD3+ % 11.7 1.3 2.7 0.7 31.3 51−77%
CD3+ abs (/ul) 114 16 39 18 1300 2500−5800/ul
CD3+4+ % 1.2 0.4 1.1 0.4 27 35−58%
CD3+4+ abs (/ul) 12 5 15 9 1120 1800−4000/ul
CD3+8+ % 9.7 0.9 2.4 0.6 5.1 12−23%
CD3+8+ abs (/ul) 95 12 34 16 213 590−1600/ul
CD16/56+ % 5.5 2.3 0.3 0.5 12 3−14%
CD16/56+ abs (/ul) 54 29 4 13 497 170−830/ul
CD19+ % 78.8 95.1 94.6 95 51.3 11−41%
CD19+ abs (/ul) 770 1208 1340 2386 2133 430−3000/ul
CD3+4+RA+62L+ % of tot CD4 <0.1 33.3 <0.1 64−92%
CD3+8+RA+62l+ % of tot CD8 8.3 15 <0.1 53−88%