Skip to main content
. Author manuscript; available in PMC: 2011 Apr 1.
Published in final edited form as: Invest Ophthalmol Vis Sci. 2010 Apr 14;51(10):4875–4883. doi: 10.1167/iovs.09-4962

Table 2.

Maximum drusen diameter (μm) for each of 12 eyes, as determined on the SD OCT (NWE interpolation) and composite CFP drusen maps. For confluent drusen, the maximum length of contiguous drusen is reported (see Figure 4). The p-value reported is obtained using a paired Student's t-test. (SD = standard deviation)

Eye SD OCT Max Length [μm) CFP Max Length [μm) Difference (SD OCT-CFP) (μm)
1 330 340 −10
2 690 600 90
3 900 690 210
4 1000 690 310
5 1010 700 310
6 1160 520 640
7 1220 830 390
8 1300 1240 60
9 1880 670 1210
10 1980 1760 220
11 1980 960 1020
12 1980 1980 0

Mean 1286 915 371 (p=0.008)