Table I.

Chronological preparations for sterile skin transplantation in GF mice.

Perioperative Preparations
Advanced Prep Stage
(≥ 24 hours)
  • ○ Spray internal surfaces of BSC with chemical sterilant

  • ○ Expose internal surfaces of BSC to UV light

  • ○ Prepare working surface of BSC with sterile drapes

  • ○ Introduce sterile container for glutaraldehyde solution

  • ○ Introduce non-sterile materials into glutaraldehyde solution

Advanced Prep Stage
(≥ 10 hours)
  • ○ Remove material from glutaraldehyde and place in sterile packaging

  • ○ Remove materials from BSC

  • ○ Expose internal surfaces of BSC to UV light

Pre-Surgery Prep Stage
(Day of Surgery)
  • ○ Assistant prepares working surface of BSC with sterile drapes using sterile technique

  • ○ Surgeon dons cap, mask, surgical gown, and sterile gloves

  • ○ Surgeon positions for surgery in BSC

Animal Transport to
BSC
  • ○ Mice are place in sterile cage set-up inclusive of wire-bar and micro-isolator lid

  • ○ Cages containing mice are placed into STSC

  • ○ Inner port cap is secured within isolator

  • ○ Transfer sleeve is removed from connection to outer transfer port of isolator and crimped

  • ○ STSC is transported to BSC sash interface

  • ○ Exposed surface of transfer sleeve is sprayed with chemical sterilant

  • ○ Cages with mice are grasped by surgeon at sash interface and removed from STSC

  • ○ Cages are positioned in the middle of the BSC working space

Surgery Prep
  • ○ Surgical equipment is passed to surgeon using sterile technique at the BSC sash interface

  • ○ Surgeon prepares fiber optic light at right of BSC sash interface with assistance

  • ○ Surgeon prepares surgical work space for surgery

Animal Transport to
Isolator
  • ○ Mice are transferred within BSC from recovery cage to sterile transport container

  • ○ Sterile transport container is placed within sterile transport cage and handed out of BSC

  • ○ Cage is transported to recovery isolator which has a sterile transfer port

  • ○ Assistant wearing sterile gloves is prepared

  • ○ External port cap is removed and transport cage lid is opened

  • ○ Assistant wearing sterile gloves removes sterile transport container from cage

  • ○ External surface of sterile transport container is sprayed with chemical sterilant

  • ○ Sterile transport container is placed in isolator transfer port once sprayed

  • ○ External isolator port cap is replaced and the transfer port sprayed with chemical sterilant

  • ○ Mice are introduced into isolator and removed from transport container

STSC: Sterile transport sterilization cylinder.