Published in final edited form as: J Appl Clin Med Phys. 2017 Jun 2;18(4):84–96. doi: 10.1002/acm2.12100

Table 3.

Dosimetric parameters of all ten virtual simulated IMRT plans. D 95: the minimal dose to 95% of the PTV, D5: minimal dose to 5% of the PTV, Dmean: mean dose to the PTV, CI: conformal index, the ratio between PTV and volume receiving dose larger than prescription dose, HI: homogeneity index, the difference between D5 and D95, divided by Dmean.

Virtual IMRT plan pt 1 pt 2 pt 3 pt 4 pt 5 pt 6 pt 7 pt 8 pt 9 pt 10 mean sd
D95 [cGy] 3227 3276 3082 3102 3026 3220 3235 3092 3111 3135 3151 78
Dmean [cGy] 3731 3667 3811 3693 3681 3802 3649 3649 3633 3770 3709 63
V33 [%] 93.4 94.3 91.2 90.7 91.1 93.3 92.3 90.1 90.5 92.2 91.9 1.4
volume of 33Gy + [cc] 35.6 129.2 87.2 84.0 112.2 50.1 53.4 108.9 42.3 101.6 80.4 31.3
volume of PTV [cc] 29.7 117.2 86.9 81.2 104.1 50.1 57.4 115.0 44.3 95.8 78.2 29.4
CI [ratio] 1.20 1.10 1.00 1.03 1.08 1.00 0.93 0.95 0.95 1.06 1.03 0.08
D5 [cGy] 4001 4012 4157 4053 3958 4141 3892 3952 3893 4144 4020 96
HI [ratio] 0.21 0.20 0.28 0.26 0.25 0.24 0.18 0.24 0.22 0.27 0.23 0.03