Coronary computed tomography angiography (CCTA) has made huge strides over the past 20+ years, from a niche, somewhat cumbersome imaging modality to a rapid, highly accurate, Level 1A guideline recommendation for chest pain evaluation. However, with rapid growth come precipitous challenges. At present, there are limited expert readers in CCTA, and that number will only get worse with the expected explosion of CCTA ordering over the coming years.1 With current training requirements and the need for hundreds of mentored CCTA scans to achieve competency, there is no way to easily fill the void.2 This is further exacerbated by the increasingly more complex disease evaluated with CCTA, including plaque burden and high-risk plaque features, which has manifested into an urgent need for robust yet streamlined computed tomography (CT) coronary evaluation. A potential solution is the application of artificial intelligence (AI) and machine learning to CCTA for both coronary stenosis and atherosclerotic plaque analysis. A number of recent studies showed that application of AI for CCTA evaluation had good diagnostic accuracy and correlation with expert readers or invasive coronary angiography (Table 1).

Table 1.

Per-Vessel Level Data for AI Analysis of CCTA (All Stenosis)

First Author Year N/No. of Vessels Comparator AI Maker/Type Diagnostic Accuracy Sens Spec Correlation or Agreementa
Choi4 2021 232/924 Level 3 readers CLEERLY -- 77 (--) 98 (--) R = 0.92
Khasanova5 2022 50/200 Level 3 readers HeartFlow -- -- -- L3 k = 0.46
AI k = 0.71
Yi6 2022 71/213 ICA CoronaryDoc 80 (74-85) 74 (65-82) 86 (77-91) k = 0.39
Liu7 2021 165/680 Level 1-3 readers, ICA CoronaryDoc 89 (87-91) 81 (76-86) 94 (81-96) AUC = 90
Griffin8 2023 303/848 ICA CLEERLY -- -- -- R = 0.73
Ihdayhid3 2024 769/3,012 Level 3 reader CNN 90 (88-91) 91 (89-92) 89 (87-90) AUC = 90

AI = artificial intelligence; AUC = receiver operator curve area under the curve; CNN = convolutional neural network; k = kappa agreement; R = Pearson’s coefficient; Sens = sensitivity; Spec = specificity.

a

Interobserver agreement.

In this issue of JACC: Advances, Ihdayhid et al3 present a fully automated, unsupervised AI application to evaluate coronary artery stenosis as well as high-risk plaque characteristics with CCTA. This study from 4 centers developed a deep learning AI algorithm with training and validation cohorts, followed by 769 patients (with 3,012 coronary arteries) for the testing cohort. Obstructive coronary artery disease (CAD) (>50% stenosis and CAD Reporting and Data System 3-5) was present in 35% of patients. Overall agreement with per vessel and per patient analyses was good at 71% and fair at 55.5%, respectively, with better agreement for obstructive CAD of 93.6% and 87.1%, respectively. This supports data from the other studies, where the highest discrepancies were in diagnosis of nonobstructive (<50% stenosis) CAD. It is important to point out that the current study did not require any human input, unlike the prior “semi-automated” AI studies. These data also compare favorably to prior studies, including the similarly designed CLARIFY study4 (Table 1). In the smaller number of 45 patients with high-risk plaque features identified by expert level 3 readers, diagnostic accuracy ranged from 84% to 90% for the 20% of vessels with high risk plaque. The total time required for AI coronary analysis was approximately 2 minutes.

The question is whether we are witnessing a revolution or the more measured, fussy evolution of AI technology for CCTA. The data strongly suggest the latter. The current study is similar to the other studies in that AI is no panacea—the AI CCTA diagnostic accuracy measures remain <100% and are quite variable whether one considers patient, coronary vessel or segments, or when considering all stenosis levels or only obstructive CAD (>50% or >70%). While the numbers in Ihdayhid et al3 are comparatively large for an imaging study, they are somewhat limited for the many thousands of data points often needed for optimal AI training. This is especially true of the high-risk plaque, where the small number of patients and coronary arteries studied (N = 45 and N = 325, respectively) were likely underpowered for robust conclusions. Further, the current study also only used one level 3 reader for each study, which could affect the ground truth and thus the accuracy of data, for better or for worse. Fortunately, the data appear within range of prior studies suggesting utility of the current algorithm, but with some caution.

When considering Ihdayhid et al3 and the other prior studies, some truths and future directions become clear. First, current iterations of AI CCTA for stenosis appear to be similar but not superior to expert readers such that the net benefit is primarily the rapidity of quantitative information. Given the expected limited expert readers in the coming years and the need for efficiency, this is a desirable benefit. Second, AI is still subject to the limitations of CT for nonevaluable scans and segments (3% of patients and an unknown number of vessels/segments in the current study) and it is likely CT technologic evolution and not AI that will affect this favorably. Third, CCTA AI data are generally compared to “bronze” standards of invasive coronary angiography and human Level 3 CCTA readers with their well-known, well-described intraobserver and interobserver variabilities. This is especially true with total plaque and high-risk plaque features. This makes a “ground truth” somewhat elusive although pathologic studies and planned studies with multimodality imaging, including intracoronary imaging, with the INVICTUS imaging registry study (NCT04066062), will provide reassurance. Fourth, despite the Standards for Reporting of Diagnostic Accuracy Studies requirements, there is a lack of uniform reporting of diagnostic accuracy measures for patient and vessel level and for all stenoses and as categorical stenoses in the current and prior reports (Table 1). This makes comparison between the different types of AI nearly impossible. Guidelines for reporting AI CCTA data are clearly needed and their development and subsequent adoption are an anticipated and much needed part of the evolution. Finally, implementation of AI may be time-saving, but needs to be balanced against the potential costs of technology, especially if an additional cost burden per scan to the patient. The lure of efficiency is strong but must be balanced into a cost-benefit analysis.

Over a relatively short period of time, AI/machine learning application to CCTA evaluation has shown great promise to make coronary imaging more efficient for a range of reader expertise and for the type and degree of CAD. Without the application of streamlined CCTA analysis with AI or other technologies, it is unlikely that imagers will be able to meet the demand for CCTA in the coming years. Studies like those provided by Ihdayhid et al3 are critical to our trust and adoption of the many AI applications for coronary analysis, but there is clearly additional work to do. Regardless, this is yet one more step in the evolution toward the seeming eventual revolution of CCTA evaluation with AI.

Funding support and author disclosures

Dr Branch has industry relationships with Bayer, Amgen, Novartis, Hanmi, Kestra, and Janssen.

Footnotes

The author attests they are in compliance with human studies committees and animal welfare regulations of the author’s institution and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center.

References

  • 1.Global Cardiac Computed Tomography (CCT) Market – Industry Trends and Forecast to 2028. Data Bridge Market Research; 2022. [Google Scholar]
  • 2.Chow B.J.W., Yam Y., Alenazy A., et al. Are training programs ready for the rapid adoption of CCTA? J Am Coll Cardiol Img. 2021;14:1584–1593. doi: 10.1016/j.jcmg.2021.01.040. [DOI] [PubMed] [Google Scholar]
  • 3.Ihdayhid A.R., Sehly A., He A., et al. Coronary artery stenosis and high-risk plaque assessed with an unsupervised fully automated deep learning technique. JACC Adv. 2024;3:100861. doi: 10.1016/j.jacadv.2024.100861. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Choi A.D., Marques H., Kumar V., et al. CT evaluation by artificial intelligence for atherosclerosis, stenosis and vascular morphology (CLARIFY): a multi-center, international study. J Cardiovasc Comput Tomogr. 2021;15:470–476. doi: 10.1016/j.jcct.2021.05.004. [DOI] [PubMed] [Google Scholar]
  • 5.Khasanova E., Indraratna P., Miranda P., et al. Head to head comparison reproducibility and inter-reader agreement of an AI based coronary stenosis algorithm vs level 3 readers. J Cardiovasc Comput Tomogr. 2022;16:533–535. doi: 10.1016/j.jcct.2022.04.005. [DOI] [PubMed] [Google Scholar]
  • 6.Yi Y., Xu C., Guo N., et al. Performance of an artificial intelligence-based application for the detection of plaque-based stenosis on monoenergetic coronary CT angiography: validation by invasive coronary angiography. Acad Radiol. 2022;29:S49–S58. doi: 10.1016/j.acra.2021.10.027. [DOI] [PubMed] [Google Scholar]
  • 7.Liu C.Y., Tang C.X., Zhang X.L., et al. Deep learning powered coronary CT angiography for detecting obstructive coronary artery disease: the effect of reader experience, calcification and image quality. Eur J Radiol. 2021;142 doi: 10.1016/j.ejrad.2021.109835. [DOI] [PubMed] [Google Scholar]
  • 8.Griffin W.F., Choi A.D., Riess J.S., et al. AI evaluation of stenosis on coronary CTA, comparison with quantitative coronary angiography and fractional flow reserve: a CREDENCE trial substudy. J Am Coll Cardiol Img. 2023;16:193–205. doi: 10.1016/j.jcmg.2021.10.020. [DOI] [PubMed] [Google Scholar]

Articles from JACC: Advances are provided here courtesy of Elsevier

RESOURCES