Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2025 May 19.
Published in final edited form as: N Engl J Med. 2025 Feb 12;392(10):1033–1034. doi: 10.1056/NEJMc2414937

Pulse Oximetry and Skin Tone in Children (POSTer-Child)

Joseph R Starnes 1, Wendi Welch 1, Christopher C Henderson 1, Stephen Hudson 1, Scott Risney 1, George T Nicholson 1, Thomas P Doyle 1, Dana R Janssen 1, Bevan P Londergan 1, David A Parra 1, James C Slaughter 2, Muktar H Aliyu 2, John A Graves 2, Jonathan H Soslow 1
PMCID: PMC12087261  NIHMSID: NIHMS2055506  PMID: 39938116

To the Editor:

Retrospective studies have found overestimation of oxygen saturation by pulse oximetry in adult and pediatric patients from races that may be associated with darker skin.1 These retrospective studies share key limitations, including race as a poor surrogate for skin tone and paired pulse oximetry (SpO2) and arterial saturation (SaO2) measurements in the medical record. Limited prospective laboratory-based2 and clinical studies3,4 using measured skin tone in adults have found worse performance among patients with darker skin. There have been very limited prospective studies in children.5

We enrolled 320 patients under 21 years of age undergoing cardiac catheterization in 2024. Skin tone was measured using a spectrophotometer. SpO2 was recorded using two pulse oximeters (Nellcor and Masimo) at the exact time of fractional saturation measured by co-oximetry. Pulse oximetry bias (SpO2-SaO2), precision (standard deviation of bias), accuracy root mean square error (ARMS), and occult hypoxemia (SaO2<88% when SpO2≥92%) were calculated. Additional methodological details are available in the Supplementary Appendix. The population was similar to the US population but showed relative underrepresentation of Hispanic children (Table S4). A total of 48 (15.1%) patients identified as Black, and 44 (13.8%) identified as Hispanic.

Average bias for the Nellcor device was 1.32% and for the Masimo device was 1.88% (Table 1). Bias was higher among children with darker skin (ITA categories 5-6) compared to children with lighter skin (ITA categories 1-2) for both pulse oximeters (p<0.001). Precision and ARMS were also higher for children with darker skin. ARMS was substantially higher than the FDA cutoff of three for children in ITA category 5-6. Occult hypoxemia was present in 7.1% of children in ITA category 5-6 for the Nellcor device and 8.3% for the Masimo device. This was higher than the 0.0% and 3.4% seen, respectively, for children in ITA category 1-2.

Table 1:

Pulse oximeter performance by skin tone*

ITA 1-2 (Lightest) ITA 3-4 ITA 5-6 (Darkest) Overall
Nellcor n=132 n=112 n=75 n=319
 Bias (%) 0.86 (0.44, 1.27) 1.12 (0.68, 1.55) 2.43 (1.64, 3.21) 1.32 (1.01, 1.62)
 Precision (%) 2.41 (2.15, 2.74) 2.35 (2.08, 2.71) 3.47 (2.99, 4.13) 2.74 (2.54, 2.97)
 ARMS 2.55 (2.14, 2.96) 2.59 (2.01, 3.17) 4.21 (3.34, 5.09) 3.04 (2.66 3.41)
 Occult Hypoxemia 0/81 (0.0%) 2/84 (2.4%) 4/56 (7.1%) 6/221 (2.7%)
Masimo n=126 n=108 n=69 n=303
 Bias (%) 1.37 (0.85, 1.88) 1.34 (0.90, 1.79) 3.67 (2.74, 4.59) 1.88 (1.52, 2.24)
 Precision (%) 2.97 (2.64, 3.38) 2.35 (2.08, 2.72) 3.89 (3.33, 4.68) 3.15 (2.92, 3.43)
 ARMS 3.25 (2.59, 3.92) 2.70 (2.10, 3.30) 5.33 (4.17, 6.48) 3.67 (3.17, 4.17)
 Occult Hypoxemia 3/88 (3.4%) 3/89 (3.4%) 5/60 (8.3%) 11/237 (4.6%)
*

Bias, precision, and ARMS are presented as value (95%CI); Occult hypoxemia presented as n/N (%)

ITA categories are as previously described by Del Bino et al.; 1=very light, 2=light, 3=intermediate, 4=tan, 5=brown, 6=dark

SpO2≥92% when SaO2<88%; denominator is patients with SpO2≥92%

We report a prospective study in children measuring overestimation of saturation by pulse oximetry attributable to skin tone. This overestimation could lead to undertreatment of hypoxemia and contribute to racial inequities in outcomes. Additional studies are needed in poulations with greater proportion of individuals with darker skin tone. Our findings emphasize that current FDA guidance for pulse oximeter validation (https://www.fda.gov/media/72470/download?attachment), which recommends only limited involvement of darkly pigmented individuals without a formal definition, is inadequate in ensuring equity in pulse oximetry accuracy. New guidance is currently under consideration. Based on these results, there is potential for improvement in both bias and precision.

Supplementary Material

Supplementary Appendix

Funding

This work was supported by grant T32 HS026122 from the Agency for Healthcare Research and Quality (JRS). The content is solely the responsibility of the authors and does not necessarily represent the official views of the Agency for Healthcare Research and Quality. This work was supported in part by the Vanderbilt CTSA grant UL1TR002243 from NCATS/NIH. This work was supported by the Jordan Hackett Foundation (JRS).

Disclosure forms provided by the authors are available with the full text of this letter at NEJM.org.

Footnotes

Publisher's Disclaimer: This is an Author Accepted Manuscript, which is the version after external peer review and before publication in the Journal. The publisher’s version of record, which includes all New England Journal of Medicine editing and enhancements, is available at https://www.nejm.org/doi/full/10.1056/NEJMc2414937.

References

  • 1.Martin D, Johns C, Sorrell L, et al. Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic review. Br J Anaesth 2024;132(5):945–56. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Gudelunas MK, Lipnick M, Hendrickson C, et al. Low Perfusion and Missed Diagnosis of Hypoxemia by Pulse Oximetry in Darkly Pigmented Skin: A Prospective Study. Anesth Analg 2024;138(3):552–61. [DOI] [PubMed] [Google Scholar]
  • 3.Hao S, Dempsey K, Matos J, et al. Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study. Crit Care Explor 2024;6(9):e1133. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Fawzy A, Ali H, Dziedzic PH, et al. Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study. Am J Respir Crit Care Med 2024; [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Foglia EE, Whyte RK, Chaudhary A, et al. The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia. J Pediatr 2017;182:375–377.e2. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Appendix

RESOURCES