Skip to main content
Annals of Surgery logoLink to Annals of Surgery
. 1984 Mar;199(3):372–374. doi: 10.1097/00000658-198403000-00021

Bilateral pneumothoraces secondary to latrogenic buffalo chest. An unusual complication of median sternotomy and subclavian vein catheterization.

G R Schorlemmer, R K Khouri, G F Murray, G Johnson Jr
PMCID: PMC1353408  PMID: 6703799

Abstract

Pneumothorax following subclavian venipuncture is a well-known risk. Less well recognized is the potential for life-threatening bilateral pneumothoraces occurring at the time of subclavian vein catheterization in patients who have previously undergone median sternotomy. Inadvertent bilateral pleural entry at the time of sternotomy may result in a common pleural space which subsequently places the patient in special jeopardy when the complication of pneumothorax occurs. This report documents the successful management of this important sequence of complications associated with now widely applied therapeutic interventions.

Full text

PDF
372

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. AUBANIAC R. L'injection intraveineuse sous-claviculaire; avantages et technique. Presse Med. 1952 Oct 25;60(68):1456–1456. [PubMed] [Google Scholar]
  2. Bernard R. W., Stahl W. M. Subclavian vein catheterizations: a prospective study. I. Non-infectious complications. Ann Surg. 1971 Feb;173(2):184–190. doi: 10.1097/00000658-197102000-00002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Johnson C. L., Lazarchick J., Lynn H. B. Subclavian venipuncture: preventable complications; report of two cases. Mayo Clin Proc. 1970 Oct;45(10):712–719. [PubMed] [Google Scholar]
  4. KEERI-SZANTO M. The subclavian vein, a constant and convenient intravenous injection site. AMA Arch Surg. 1956 Jan;72(1):179–181. [PubMed] [Google Scholar]
  5. Maggs P. R., Schwaber J. R. Fatal bilateral pneumothoraces complicating subclavian vein catheterization. Chest. 1977 Apr;71(4):552–553. doi: 10.1378/chest.71.4.552. [DOI] [PubMed] [Google Scholar]
  6. Merk E. A., Rush B. F., Jr Emergency subclavian vein catheterization and intravenous hyperalimentation. Am J Surg. 1975 Mar;129(3):266–268. doi: 10.1016/0002-9610(75)90237-8. [DOI] [PubMed] [Google Scholar]
  7. Nehme A. E. Swan-Ganz catheter: comparison of insertion techniques. Arch Surg. 1980 Oct;115(10):1194–1196. doi: 10.1001/archsurg.1980.01380100042009. [DOI] [PubMed] [Google Scholar]
  8. SMITH B. E., MODELL J. H., GAUB M. L., MOYA F. COMPLICATIONS OF SUBCLAVIAN VEIN CATHETERIZATION. Arch Surg. 1965 Feb;90:228–229. doi: 10.1001/archsurg.1965.01320080052011. [DOI] [PubMed] [Google Scholar]
  9. WILSON J. N., GROW J. B., DEMONG C. V., PREVEDEL A. E., OWENS J. C. Central venous pressure in optimal blood volume maintenance. Arch Surg. 1962 Oct;85:563–578. doi: 10.1001/archsurg.1962.01310040035005. [DOI] [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins