Skip to main content
Gut logoLink to Gut
. 1992 Jan;33(1):92–97. doi: 10.1136/gut.33.1.92

Estimation of total hepatic blood flow by duplex ultrasound.

K M Carlisle 1, M Halliwell 1, A E Read 1, P N Wells 1
PMCID: PMC1373871  PMID: 1740284

Abstract

The volume flow rate of blood in the portal vein and the hepatic artery was measured using a duplex ultrasound system. Two sections of the hepatic artery were studied; the common hepatic artery where measurements were made just after the bifurcation of the coeliac axis to splenic and hepatic arteries and the hepatic artery itself, where measurements were made just proximal to the porta hepatis in a straight stretch of artery overlying the portal vein. Total hepatic blood flow was taken as the sum of hepatic artery and portal vein flows. A group of 10 normal healthy volunteers in the fasting state was studied. The mean (SD) volume blood flow in the vessels was measured to be: hepatic artery 3.5 (45%) ml/min/kg, common hepatic artery 6.9 (30%) ml/min+/kg, portal vein 13.5 (21%) ml/min/kg, total hepatic flow 17.0 (16%) ml/min/kg.

Full text

PDF
92

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Angelsen B. A. A theoretical study of the scattering of ultrasound from blood. IEEE Trans Biomed Eng. 1980 Feb;27(2):61–67. doi: 10.1109/TBME.1980.326708. [DOI] [PubMed] [Google Scholar]
  2. Brown H. S., Halliwell M., Qamar M., Read A. E., Evans J. M., Wells P. N. Measurement of normal portal venous blood flow by Doppler ultrasound. Gut. 1989 Apr;30(4):503–509. doi: 10.1136/gut.30.4.503. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Gill R. W. Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol. 1985 Jul-Aug;11(4):625–641. doi: 10.1016/0301-5629(85)90035-3. [DOI] [PubMed] [Google Scholar]
  4. McDicken W. N. A versatile test-object for the calibration of ultrasonic Doppler flow instruments. Ultrasound Med Biol. 1986 Mar;12(3):245–249. doi: 10.1016/0301-5629(86)90315-7. [DOI] [PubMed] [Google Scholar]
  5. Moriyasu F., Ban N., Nishida O., Nakamura T., Miyake T., Uchino H., Kanematsu Y., Koizumi S. Clinical application of an ultrasonic duplex system in the quantitative measurement of portal blood flow. J Clin Ultrasound. 1986 Oct;14(8):579–588. doi: 10.1002/jcu.1870140802. [DOI] [PubMed] [Google Scholar]
  6. Nakamura T., Moriyasu F., Ban N., Nishida O., Tamada T., Kawasaki T., Sakai M., Uchino H. Quantitative measurement of abdominal arterial blood flow using image-directed Doppler ultrasonography: superior mesenteric, splenic, and common hepatic arterial blood flow in normal adults. J Clin Ultrasound. 1989 May;17(4):261–268. doi: 10.1002/jcu.1870170406. [DOI] [PubMed] [Google Scholar]
  7. PRICE J. B., Jr, BRITTON R. C., PETERSON L. M., REILLY J. W., VOORHEES A. B. THE VALIDITY OF CHRONIC HEPATIC BLOOD FLOW MEASUREMENTS OBTAINED BY THE ELECTROMAGNETIC FLOW METER. J Surg Res. 1965 Jul;5:313–317. doi: 10.1016/s0022-4804(65)80075-0. [DOI] [PubMed] [Google Scholar]
  8. Qamar M. I., Read A. E., Skidmore R., Evans J. M., Williamson R. C. Transcutaneous Doppler ultrasound measurement of coeliac axis blood flow in man. Br J Surg. 1985 May;72(5):391–393. doi: 10.1002/bjs.1800720519. [DOI] [PubMed] [Google Scholar]
  9. Strandell T., Erwald R., Kulling K. G., Lundbergh P., Marions O., Wiechel K. L. Measurement of dual hepatic blood flow in awake patients. J Appl Physiol. 1973 Nov;35(5):755–761. doi: 10.1152/jappl.1973.35.5.755. [DOI] [PubMed] [Google Scholar]
  10. Zoli M., Marchesini G., Cordiani M. R., Pisi P., Brunori A., Trono A., Pisi E. Echo-Doppler measurement of splanchnic blood flow in control and cirrhotic subjects. J Clin Ultrasound. 1986 Jul-Aug;14(6):429–435. doi: 10.1002/jcu.1870140605. [DOI] [PubMed] [Google Scholar]

Articles from Gut are provided here courtesy of BMJ Publishing Group

RESOURCES